The minimum strength of banding shall be:
Safety Factor x ½ weight of units x secant of bridle angle.
Secant of bridle angle of 40 degrees is 1.3.
Total wire strength (answer from above) divided by strength provided by a single wire = required wires.
Example:
Unit weight 4,000 lbs.
Individual wire strength = 1,758 lbs.
Safety factor = 4
Equation:
2,000 x 4 x 1.3 ¸ 1,758 = 5.9 wires, i.e. 6 wires.